Congratulations and Thank-you for purchasing the EcoSunTec Infrared Moist Air Purifying Space Heater. You are now the owner of the world's most advanced Infrared Space Heater that purifies the air and combines infrared heat with water vapor mist for maximum efficiency, savings and comfort in your home zone heating. 

Space age technology that uses the power of the sun to zone heat your home efficiently and economically. The EcoSunTec 3 Way Heater can save you up to 40% on heating bills by warming the atmosphere evenly. With infrared heat and humidifying micro burst technology, we bring you optimal comfort for a fraction of your usual heating cost.

Enjoy the therapeutic effects of infrared heat now being used in many medical therapies by simply heating your room. The comfortable and healthy way to heat your room while adding humidity and filtering impurities out of the air.
                                                                        
PLEASE READ ALL INSTRUCTIONS BEFORE USING THE HEATER
This is a text only version for a full manual including photos please contact us

EcoSunTec
Infrared Moist Air Purifying Space Heater 
IMAP-1000
EcoSunTec 3 Way Heating System

Operation and Warranty Manual


PLEASE READ ALL INSTRUCTIONS BEFORE USING THE HEATER



KEEP THIS MANUAL FOR FUTURE REFERENCE


Safety Precautions……………………………..……1
Proper Use and Handling…………………………..1-2
Unpacking..……………….……………..…….……...3
Tip Over Safety Feature….……………………..…..3
Operation……………………………….……..…..…..4
Remote Control………………………...…………….5
Humidifier Feature…………………..…….……..…..6
Humidifier Maintenance Tips…………….……..….7
Timer…………………………………..…….………....8
Air Filter Maintenance……….……………………...9-10
Humidifier Cleaning and Maintenance…………..11-12
Trouble Shooting……………………..….……….…13
Efficient Heating Tips…………………….…………14
30 Day Return Guarantee………………………..…15
Three Year Limited Warranty………………………16
Warranty Claim procedure……………….………....17
Special Offer…………………………………………..18
Notes…………………………………………………...19
Warranty Card………………………………………...20
                                                                

        
IMPORTANT INSTRUCTIONS
SAFETY PRECAUTIONS
WARNING:
Improper use of this heater could result in the risk of electric shock, fire and possible injury to individuals.
WARNING:Do not open the heater casing or attempt any repairs or service. Any required service (other than filter maintenance on
page 10) should only be performed by an
Authorized Service and Repair Representative.
To do otherwise will void your warranty.


Proper Use and Handling

Never open, alter or repair the heater as it will void the warranty.

Do not use or store the heater with any other machinery or near strong magnets.

Do not plug the heater into an extension cord, waiver bar, power strip, surge protector, multi outlet adapter, grounding adapter, outlet style air fresheners or Christmas lights.

Make sure the power cord is in good condition before plugging in for use.

Do not run the power cord underneath a carpet or rug.

Plug heater into an  AC110V (15AMP) outlet .


Wait until after the fan stops running approximately 60 seconds to unplug heater after turning the unit off. Always unplug heater when not in use.

Do not spill anything on the heater.

Do not operate, set or store the heater near combustible objects such as vapors, gaseous fumes, spray cans, paint or any other flammable liquids.

Do not set heater close to furniture, pillows, bedding, papers, clothes, curtains or flammable items.

Do not sit on the heater, put items on the heater, hang things over the heater or cover the air outlet opening of the heater.

Do not insert anything into the exhaust, ventilation or heater outlet openings of the heater.

Do not use heater for other purposes such as a dryer.

Do not place the heater on the TV, other appliances, tables, beds, chairs or on shaky surfaces.

Do not operate or store the heater in wet, moist and humid areas or areas with standing water such as bathrooms, swimming areas, laundry rooms or outdoors.

Do not handle heater or plug while wet or with wet hands.

Do not operate in dusty, dirty, oily areas or construction sites.

Do not expose body parts directly to the heat for prolonged periods of time.

Do not touch or gaze into the heater heat outlet.

Do not use heater while sleeping.

The heater grill is hot when in use
, allow 30 minutes to cool.

Use handles when moving this heater after emptying all the fluids from the humidity tray unit.


Do not leave heater unattended. The infrared element never reaches a temperature capable of igniting any material. Always use caution whenever any heater is left operating especially around children and disabled persons.


UNPACKING
To unpack heater gently peel taped seams, fold back the flaps of the box and gently roll entire box upside down. Lift box off of Styrofoam packing and heater. Remove Styrofoam and all packing materials. Keep the packaging and box for summer storage and any transporting needs.

Set the unpacked heater on a level and unobstructed location away from pathways where one might trip over it.

There are multiple power settings for the heater and it can be used for Small, Medium and Large sized rooms (as follows: Small 650 Watts; Medium 1100 Watts; Large 1500 Watts).


TIP OVER SAFETY FEATURE
If the EcoSunTec Infrared Moist Air Purifying Space Heater unit is tipped over the power will automatically shut off. Return it to its level position and it will resume at the pre-set default Large Room Size Setting and Temperature Setting 15. Then adjust the Room Size and Temperature as desired.

TURNING THE HEATER ON
Turn the MASTER SWITCH to the ON position so it is illuminated. Press the Power Button on the digital display. Wait for the heater to start operating in about 45 to 60 seconds. The unit will automatically come on to the pre-set Large Room Size Setting and Temperature Setting 15.
                                
SELECT THE ROOM SIZE
Select the room size setting you wish to use SMALL for a small size room, MEDIUM a medium size room or LARGE for a large size room.

TEMPERATURE SETTING
Use the heater's (1-15) up and down arrows to adjust the Temperature Setting. Once the Selected Temperature is reached the heater will maintain the temperature by cycling on and off.

TO TURN HEATER OFF
Turn the MASTER SWITCH to the OFF position. The switch light will turn off. The fan will continue to run until all of the heat has been expelled from the PTC (Positive Thermal Coefficient) heater element. After a few minutes the fan will shut off automatically. It is then safe to unplug the unit, allow it to cool about 30 minutes to drain the water from the humidity tray and/or remove the filter for cleaning.

Do Not Unplug the Heater Until the Fan Stops.
Keep heater unplugged when not in use.
  

REMOTE CONTROL OPERATION
The remote control requires 2 "AA" batteries installed into the battery compartment on the back of the remote control.
Batteries not included.

Turn the MASTER SWITCH on the heater ON. Light will be illuminated.

To use the remote control, point the remote at the heater and make selections.


HUMIDIFIER FEATURE
The heater can be safely and effectively operated without water producing dry heat only. When the water is diminished from the tank the heater will automatically turn off the humidifier component.

To Use Moist Heat Humidifying Feature
1) Use caution when handling the humidifier unit as the plastic can be hot.

2) Make sure the heater is turned off. Allow the heater to cool for 30 minutes.

3) Open the cover plate on the side of the heater; unclip at the bottom to release. Slide the humidifier tray assembly from the humidifier chamber. Remove the water bottle from the humidity tray unit.

4) Fill the bottle with tap water and invert the bottle into the humidity tray unit shown below. Once the water has filled the tray, refill the bottle a second time and replace it back into the humidity tray unit.
                    
5) Check for any leaking and adjust the water tank if necessary. Slide the humidity tray assembly back in place inside the humidifier chamber. Snap the door closed. The humidifier is now primed to last for approximately 8 hours.

6) Press the Humidifier feature button on in the front of the unit to use the moisture micro burst technology to improve effectiveness and efficiency.


The humidifier will cycle on for 3 minutes, shuts off for 2 minutes providing continuous savings, safety and comfort.

When the humidifier tank has emptied the "Water" indicator symbol will light up and the humidifier will shut off.

The heater can be safely and effectively operated without water.
The heater will automatically switch to dry heat feature when water tank is emptied.
To continue to use the moist heat feature refill the water tank by following steps 1 to 6.
See care and cleaning of Humidifier unit on

Pages 11 &12.

HUMIDIFIER MAINTENANCE TIPS
Clean the humidifier tank once every day that the heater humidifier is in use.

Empty the water tank if the heater is not going to be used for a few days.

CAUTION: Empty all water from the humidifier tank before lifting, storing or moving the heater. Keep water tank empty and clean when not in use.

Do not place any other things into the water tank such as oils, gas, aromatic substance, dirty water or hot water over 104F.

Use only EcoSunTec Humidifier Filters
. Available at www.ecosuntec.com or call us at 803-319-4836 or toll free at 877-326-4320.  

Allow heater 30 minutes to cool down before cleaning or draining out the humidifier container.

Beware that water may freeze under some circumstances so do not leave water in the unit when not in use. Allow the unit to cool for 30 minutes to remove the water assembly tray.

TIMER
The heater is equipped with a timer feature that will either shut the unit off after a desired amount of time or delay the time for the unit to turn on.

AUTO SHUT OFF
With the unit running at the desired temperature, press the TIMER button to the desired number of hours you would like the heater to run before shutting off.

The hours range from 2-12 hours in 2 hour increments.

With the POWER button ON and the illuminated MASTER SWITCH turned ON, set the number of hours you would like the heater to run before shutting off the unit will automatically shut off once the set amount of time has passed.

AUTO TURN ON
With the illuminated MASTER SWITCH ON, press the POWER button OFF. Press the TIMER button to the desired number of hours that you would like to delay the start of your heater.

The hours range from 2-12 hours in 2 hour increments.

Once the heater turns on it will be set at the default Large Room Size Setting and Temperature Setting 15 once the set amount of time (2-12 hours) has passed. After the 60 second warm up time the fan will start and you can then adjust the temperature as desired.

To cancel the timer, press the POWER button.


GERM KILLING AIR PURIFICATION FEATURE
The amazing revolutionary UVc (ultra violet) lamp automatically activates when the heater is on. On very rare occasion you may need to change the UVc germ killing lamp. In the unlikely event that you need to replace the UVc lamp visit http://www.ecosuntec.comc or call us at
803-319-4836 or toll free at 877-326-4320 to order.


CLEANING AND CARE
EcoSunTec Infrared Moist Air Purifying Space Heater

WASHABLE LIFETIME ELECTROSTATIC
AIR FILTER SYSTEM

The EcoSunTec Infrared Moist Air Purifying Space Heaters come equipped with a lifetime washable filter. The filter needs to be cleaned regularly. To do this, follow these steps:


WASHABLE LIFETIME
ELECTROSTATIC AIR FILTER SYSTEM

CLEAN THE AIR PURIFYING FILTER

Cleaning the filter is critical.

   

1) Turn off the heater. Allow the heater to cool 30 minutes. Then unplug the heater.

2) To remove the filter from the back of the heater grasp the filter at the bottom and push up on the filter against the springs at the top, then lift it straight out and over the brackets that hold the filter on.

3) Clean the dust and silt from the filter with a vacuum cleaner attachment or run warm tap water over the filter in the opposite direction of air flow, until water runs clear.

4) For deeper cleaning soak the filter in water mixed with a small amount of mild dish soap AND RINSE THOROUGHLY.
The filter might excrete some filtered residue, be cautious near carpeting and other stainable surfaces.

5) Shake the filter over the sink to remove excess water.
 Allow the filter to air dry completely before reinstalling on to the back of the heater.

6) DO NOT force the filter to dry using any type alternative methods other than drip dry. Let it air dry completely.

7) Reinstall the filter on to the back of the unit by pushing it up against the springs then pushing the filter in place over the brackets that hold the filter in place.

The "Temperature Limiting Control" safety feature within the unit will shut off the heater if the filter is overly dirty. If the heater stops working, turn off the master switch and allow the heater to cool down. Clean the filter following steps 1-7 on this page. Turn the heater on and resume use. If the unit continues to shut down or the unit does not reboot itself, please call EcoSunTec Technical Assistance
803-319-4836 or toll free at 877-326-4320


HUMIDIFIER CLEANING AND MAINTENANCE OF THE ASSEMBLY

CLEANING THE WATER TANK

1) Make sure the heater is turned off. Allow the heater to cool for 30 minutes if necessary.

2) Open the cover plate located on the side of the heater; unclip the clip at the bottom of the door to release. Slide the Humidifier Tray Assembly from the Humidifier Chamber. Remove the Water Tank from the Humidifier Tray Unit.

3) With some tap water and mild dish soap wash away dirt and particles in the Water Tank and tray unit. Use an old toothbrush and q-tips for hard to reach areas. Rinse thoroughly.

4) Let the Humidifier Assembly dry completely for storage then place the Water Tank in the Humidifier Tray Unit. Slide the Humidifier Tray Assembly back in its place inside Humidifier Compartment. Snap the door closed.

To refill the water tank for use follow the directions on
page 6.


CLEANING THE HUMIDIFIER FILTER

1) Pull up to release the filter inside the humidifier tray unit.

2) Pour a couple drops of mild dish soap into a gallon of hot water. Soak the humidifier filter in the tub of solution for 30 minutes. RINSE THOROUGHLY with clean water.

3) Allow the filter to dry completely before installing the filter into the humidifier tray unit and into the heater for storage.


CLEANING THE OUTSIDE OF HEATER UNIT
Use a soft dry cloth to dust the outside of the unit. If necessary use a moist cloth and mild cleaner to clean the control panel.

STORING YOUR HEATER
Store the unit in a clean dry location. Remove all water. Dry all parts completely before storing. Pack in original packaging to store.



TROUBLE SHOOTING

Heater does not turn on

Is the power cord inserted into the outlet?
Check the circuit breaker.
Is the heater tilted at all?
Check and clean the air filter.


Blows only slight air
Is something blocking the air outlet?
Check and clean the air filter.


Humidifier not working
Make sure the water tank is set properly in the humidity tray assembly.
Is the humidifier tray assembly set correctly in the compartment?
Is the pump running ?
Is the humidifier clean?

Humidifier water light is on
Is the humidifier tray assembly set correctly in the compartment?
Is the heating unit tilted?
Is the float stuck?
Is the tank filled up with water?

Unit is noisy
Is the water tank tilted?
Is the pump clogged?

Temperature Limiting Control Safety Feature
The EcoSunTec Infrared Moist Air Purifying Space Heater comes equipped with a "Temperature Limiting Control" (TLC) safety feature. Blocking of air flow will trigger the TLC.

Keep the filter clean. Check the filter often if the heater is being used in a dirty or dusty area. The filter can clog and trigger the TLC safety feature causing the heater to stop running.


Efficient Heating Tips
Try different placements of the heater to see what works best for your room.

Avoid placing the heater in drafty areas or near air filtration systems as the warm air will be exhausted too quickly. Close the cold air return to prevent the heat being drawn away. Weather seal drafty cracks around windows or doors to help insulate the room from drafts.

For more efficient heating place the heater near a warmer inside wall and direct the warm air output towards a cooler outside wall. This will draw the generated heat towards the outside wall.

Due to the humidity feature a soft heat is created bringing an evenly heated atmosphere that makes lower temperature feel warmer; 68 degrees feel like 72 degrees.

Close the hot air delivery registers and air return grills of the existing heat system if the heater is being used in an isolated area.

In rooms with large areas of bare concrete place the heater a few feet or so above the floor. Make sure the heater is in a secure spot so it won't fall. Concrete will tend to draw the heat toward itself.

Save on heating bills! Why heat rooms to 68 or more degrees when they are not in use? Try lowering your central heating system temperature. Use the EcoSunTec Infrared Moist Air Purifying Space Heater where you are spending your time.

In larger areas, place the heater in a central location. Use a ceiling fan nearby set to move the air downward, to help distribute the heat more evenly.


30 DAY RETURN GUARANTEE
This heater has a 30 day return guarantee.  If the unit is found to be defective you may return it for a replacement or a refund within 30 days of purchase.  All shipping charges to and from locations outside the Continental Lower 48 United States will be the responsibility of the customer.  In the unlikely event you need to return your heater it must be in "new condition". It must be packed in the "original shipping box" using all "original packing" to avoid damage during shipment. Also included must be the remote control, operations manual and all other materials that originally came with the unit.Contact us for a return authorization number (RAN). Call us at 803-319-4836 or toll free at 877-326-4320.  All returns must include a RAN.  Units returned without proper authorization will be charged a 25% restocking fee.If delivery is refused and the shipment is returned to our warehouse, a 25% restocking fee will apply along with a $25 original shipping charge for locations inside the Continental Lower 48 United States and additional shipping charges for locations outside the Continental Lower 48 United States.

Three Year Limited Warranty
WARRANTY: The company shall warrant this product to the original purchaser of or gift recipient to be free from defects in workmanship and materials under normal use and service for a period of three years limited to internal operational components only, excluding external cabinetry changes and a total of five years on the PTC (Positive Thermal  Coefficient) ceramic heating element from the date of purchase.
LIMITATIONS: The warranty will be null and void if any of the following occur; the mechanics of the heater and or the electrical cord and plug have been altered or tampered with in any way. Heaters that are not used correctly or not maintained according to the Operations Manual will void the warranty.
LIMITATIONS: All warranties implied by law, including the implied warranties of merchantability and fitness for a particular purpose, are expressly limited to the duration of the limited warranties set forth above.
Some jurisdictions do not allow a limitation on the length of the implied warranty so the above limitation may not apply to you. In no event shall the company be liable for any incidental or consequential damages, loss of profits or medical expenses caused by any defect, failure, misuse or malfunction of the product.
Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. The company will not be responsible for damages or losses directly or indirectly caused by misuse, abuse, accident, negligence, conditions of transportation or storage or failure to follow instructions. The company will not be responsible for any statements that are made or published, written or oral, that are inconsistent with this written warranty or which are misleading or inconsistent with the facts as published in the literature or specifications by the company.
WARRANTY RESTRICTION: This warranty is invalid if the factory-applied serial number has been altered, tampered with or removed from the product.
WARRANTY CLAIM PROCEDURE
Your warranty card must be completed and returned to us within 30 days of purchase to activate your warranty.
Failure to do so will void your warranty.
Please visit our website http://www.ecosuntec.com for numerous trouble shooting tips and possible service instructions if needed.
 If you are unable to resolve your service problem after visiting
http://www.ecosuntec.com you may contact our customer service team by calling call us at 803-319-4836 or toll free at 877-326-4320. Please have your proof of purchase, the model number and serial number handy before you make your call so we are able to assist you with the information necessary.
If we are unable to solve your problem return shipping instructions will be given to you at that time. Return of units not utilizing the "original shipping box" and "original packing" will be at the customer expense.All shipping charges to and from locations outside the Continental Lower 48 United States will be the responsibility of the customer.We recommend you insure your shipment.
CAUTION:  Please remove all water from the humidity tray assembly and make sure all parts of the unit are dry before packing and shipping.  Extra charges may be incurred by the customer due to damage caused by water left in the unit at the discretion of the company.